Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Einstein (Säo Paulo) ; 13(3): 364-369, July-Sep. 2015. tab
Article in English | LILACS | ID: lil-761948

ABSTRACT

Objective To evaluate if body surface temperature close to the central venous catheter insertion area is different when patients develop catheter-related bloodstream infections.Methods Observational cross-sectional study. Using a non-contact infrared thermometer, 3 consecutive measurements of body surface temperature were collected from 39 patients with central venous catheter on the following sites: nearby the catheter insertion area or totally implantable catheter reservoir, the equivalent contralateral region (without catheter), and forehead of the same subject.Results A total of 323 observations were collected. Respectively, both in male and female patients, disregarding the occurrence of infection, the mean temperature on the catheter area minus that on the contralateral region (mean ± standard deviation: -0.3±0.6°C versus-0.2±0.5ºC; p=0.36), and the mean temperature on the catheter area minus that on the forehead (mean ± standard deviation: -0.2±0.5°C versus-0.1±0.5ºC; p=0.3) resulted in negative values. Moreover, in infected patients, higher values were obtained on the catheter area (95%CI: 36.6-37.5ºC versus 36.3-36.5ºC; p<0.01) and by temperature subtractions: catheter area minus contralateral region (95%CI: -0.17 - +0.33ºC versus -0.33 - -0.20ºC; p=0.02) and catheter area minus forehead (95%CI: -0.02 - +0.55ºC versus-0.22 - -0.10ºC; p<0.01).Conclusion Using a non-contact infrared thermometer, patients with catheter-related bloodstream infections had higher temperature values both around catheter insertion area and in the subtraction of the temperatures on the contralateral and forehead regions from those on the catheter area.


Objetivo Avaliar se a temperatura da superfície corporal nas proximidades da área de inserção do cateter venoso central é diferente quando os pacientes desenvolvem infecções da corrente sanguínea relacionadas ao cateter.Métodos Estudo transversal observacional. Usando um termômetro infravermelho sem contato, 3 medições consecutivas de temperatura da superfície corporal foram coletadas de 39 pacientes com cateter venoso central nos seguintes locais: nas proximidades da área de inserção do cateter ou do reservatório do cateter totalmente implantável, na região contralateral equivalente (sem cateter), e na fronte do mesmo paciente.Resultados Um total de 323 observações foram coletadas. Respectivamente nos pacientes do sexo masculino e feminino, desconsiderando a ocorrência de infecção, a temperatura média na área do cateter menos a da região contralateral (média ± desvio padrão: -0,3±0,6°C versus -0,2±0,5°C; p=0,36) e a da área do cateter menos a da fronte (média ± desvio padrão: -0,2±0,5°Cversus -0,1±0,5°C; p=0,3) resultaram em valores negativos. Além disso, em pacientes infectados, foram obtidos valores mais elevados na área do cateter (IC95%: 36,6-37,5ºC versus36,3-36,5ºC; p<0,01) e nas subtrações de temperaturas: área do cateter menos região contralateral (IC95%: -0,17 - +0,33°C versus-0,33 - -0,20°C; p=0,02) e a área do cateter menos fronte (IC95%:-0,02 - +0,55°C versus -0,22 - -0,10ºC; p<0,01).Conclusão Utilizando um termômetro infravermelho sem contato, os pacientes com infecções da corrente sanguínea associadas ao cateter apresentaram valores de temperatura mais elevados, tanto ao redor da área de inserção do cateter e na subtração das temperaturas das regiões contralateral e fronte, em relação àquelas da área do cateter.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Young Adult , Catheter-Related Infections/physiopathology , Central Venous Catheters/adverse effects , Skin Temperature/physiology , Thermometry/methods , Cross-Sectional Studies , Catheter-Related Infections/diagnosis , Early Diagnosis , Forehead , Infrared Rays
2.
Rev. Assoc. Med. Bras. (1992) ; 55(2): 149-152, 2009. tab
Article in Portuguese | LILACS | ID: lil-514812

ABSTRACT

OBJETIVO: Em pacientes hospitalizados, comparar a evolução de variáveis antropométricas e a ocorrência de efeitos adversos relacionados ao consumo de suplementos nutricionais e infusão de nutrição enteral. MÉTODOS: 10 pacientes que recebiam suplementos nutricionais (Grupo SN) e 20 em nutrição enteral (Grupo NE), pareados para o gênero, idade (50 ± 21 vs 49 ± 23 anos) e afecções de base foram submetidos à avaliação antropométrica ao início e término da terapêutica. Diariamente, foi aplicado um questionário semi-estruturado referente às queixas gastrointestinais. Determinaram-se as diferenças estatísticas obtidas entre o início e o final da terapêutica (teste t para amostras dependentes) e entre os grupos de estudo (teste t para amostras independentes). RESULTADOS: A circunferência muscular do braço aumentou nos pacientes do Grupo NE (80 ± 15 vs 85 ± 15 por cento de adequação, p = 0,009) e diminuiu no Grupo SN (96 ± 14 vs 92 ± 14 por cento de adequação, p = 0,04). Náuseas e vômitos foram mais frequentes no Grupo SN (60 vs 10 por cento, p = 0,01) e as queixas relacionadas ao sabor dos produtos ocorreram em 30 por cento dos casos. CONCLUSÃO: Os pacientes que receberam suplementos nutricionais apresentaram maior ocorrência de queixas gastrointestinais e evolução desfavorável dos parâmetros antropométricos. Os dados obtidos no estudo não evidenciam o benefício da suplementação nutricional de rotina em pacientes hospitalizados.


OBJECTIVE: To compare the evolution of anthropometric variables and the occurrence of adverse effects related to the ingestion of nutritional food supplements and enteral diet administration in hospitalized patients. METHODS: The study was performed in the Clinical Medicine wards of the Hospital of the School of Medicine of Ribeirão Preto, USP, with 10 patients receiving nutrition supplements, and 20 patients under enteral nutrition therapy, paired by gender, age (50 ± 21 vs 49 ± 23 years) and basic afflictions. All were volunteers submitted to anthropometric evaluation at the beginning and end of nutritional therapy, utilizing standard techniques. A semi-structured questionnaire was applied daily referring to gastrointestinal complaints. Statistical differences between onset and final results (t-test for dependent samples) and between-group differences (t-test for independent samples) were estimated. RESULTS: Arm muscle circumference increased in patients receiving enteral nutrition therapy (80 ± 15 vs 85 ± 15 percent adequacy, p = 0.009) and decreased in those receiving nutritional supplements (96 ± 14 vs 92 ± 14 percent adequacy, p = 0.04). Nausea and vomiting were more frequent in the latter (60 vs 10 percent, p = 0.01); complaints about taste of the products were reported by 30 percent of the cases. CONCLUSION: Patients who received oral nutrition supplements reported gastrointestinal complaints and had a less favorable anthropometric evolution. Study data did not disclose the benefit of routine nutrition supplements for hospitalized patients.


Subject(s)
Female , Humans , Male , Middle Aged , Dietary Supplements/adverse effects , Enteral Nutrition/adverse effects , Nausea/etiology , Skinfold Thickness , Vomiting/etiology , Administration, Oral , Anthropometry , Chi-Square Distribution , Hospitalization/statistics & numerical data
3.
Rev. nutr ; 18(2): 261-269, mar.-abr. 2005. tab, graf
Article in Portuguese | LILACS | ID: lil-415956

ABSTRACT

Cateteres venosos totalmente implantados são utilizados em pacientes com síndrome do intestino curto, para realizar o suporte nutricional parenteral, o qual mantém estes pacientes vivos, pois fornece-lhes nutrientes que são absorvidos pela via digestiva. No entanto, estes cateteres não são isentos de complicações. As infecções relacionadas aos cateteres venosos são as complicações mais temidas e sua incidência varia de 3 por cento a 20 por cento, aumentando em pacientes mais graves. O objetivo do presente estudo é descrever as complicações infecciosas em pacientes recebendo nutrição parenteral por meio de cateteres venosos totalmente implantados. Tais cateteres são utilizados pela Divisão de Nutrição Clínica do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, para realizar o suporte nutricional parenteral em pacientes submetidos a ressecções extensas de intestino delgado. Foram avaliadas as complicações infecciosas ocorridas com 21 cateteres, implantados em 16 pacientes. O tempo de permanência dos cateteres foi de 768±664,3 dias (mediana 529 dias) e a taxa de infecção foi de 0,029 infecções/paciente/ano, resultados que se comparam às taxas de infecção observadas em países desenvolvidos. Concluiu-se que os cuidados observados no manuseio destes cateteres foram de fundamental importância para diminuir a incidência de infecção nestes pacientes.


Subject(s)
Humans , Sepsis , Catheters, Indwelling/adverse effects , Catheters, Indwelling/statistics & numerical data , Parenteral Nutrition/instrumentation
4.
Rev. nutr. PUCCAMP ; 5(2): 121-42, jul.-dez. 1992. ilus, tab
Article in Portuguese | LILACS | ID: lil-147959

ABSTRACT

O presente artigo descreve os dados de antropometria utilizados para avaliaçäo do estado nutricional de indivíduos adultos. As seguintes medidas antropométricas säo comentadas: peso, altura, circunferência do braço e pregas cutâneas. Também säo descritas as medidas derivadas já citadas, como por exemplo, circunferência muscular e índice de gordura do braço. Conclue-se que a antropometria é um método näo invasivo, de fácil execuçäo, rápido, de baixo custo e que tem valor preditivo acurado para identificar populaçöes de risco nutricional e de saúde em geral


Subject(s)
Humans , Male , Female , Adolescent , Adult , Mid-Upper Arm Circumference , Anthropometry , Nutritional Status/physiology
SELECTION OF CITATIONS
SEARCH DETAIL